NR. 1/2005

|
|
|
|
|
|
|
|
|
Zastosowanie
perymetrii o zdwojonej częstotliwości w wykrywaniu jaskry u
dzieci i młodzieży
Use of Frequency Doubling Perimetry in Glaucoma Detection in
Children and Adolescents
Małgorzata Mrugacz, Alina
Bakunowicz-Łazarczyk, Beata Urban, Nella Żywalewska
Klinika Okulistyki Dziecięcej Akademii Medycznej w Białymstoku
Kierownik: prof. dr hab. med. Alina Bakunowicz-Łazarczyk |
|
|
|
|
|
|
|
| Summary: |
Aim: To evaluate
the diagnostic usefulness of the use of
frequency-doubling technology (FDT) perimetry in
children and adolescents with glaucoma.
Material and methods: 30 patients with suspected
glaucoma aged 12-18 years and 25 normal control subjects
aged 13-18 years were enclosed in the study. All
participants underwent ophthalmic examination with the
measure of the intraocular pressure and gonioscopy, and
standard achromatic automated perimetry and FDT
perimetry.
Results: 10 (33%) glaucoma patients had visual
field defects in FDT perimetry; visual field in
automated perimetry was normal.
Conclusions: FDT perimetry have the potential
role for the glaucomatous visual field loss detection in
children and adolescents. Visual field defects may be
detected earlier than in standard perimetry. |
| |
|
| Key words: |
glaucoma, frequency
doubling perimetry. |
|
|
|
|
|
|
|
|