NR 6/2003

|
|
|
|
|
|
|
|
|
Powikłania po zabiegu LASIK - zmarszczki i
fałdy płatka rogówki - materiał własny
LASer In situ Keratomileusis complications - corneal
flap striae and folds - own material
Dorota Wyględowska-Promieńska, Stanisława Gierek-Ciaciura
Z I Katedry i Kliniki Okulistyki ¦l±skiej Akademii Medycznej w Katowicach
Kierownik: prof. dr hab. n. med. Ariadna Gierek-Łapińska |
|
|
| Summary: |
Purpose: The purpose of this study was, to
classify striae and folds seen after LASIK as an early and late complications.
Material and methods: At the First Department and Clinique of
Ophthalmology Silesian Medical School in Katowice LASIK procedure was performed since
1997. The material consisted of 155 eyes of 120 patients. There was a 24- month
observation period after the procedure. The corneal cap techniques were used with
Chiron-Adatomed Automated Corneal Shaper (mikrokeratom). The stromal bed was fotoablated
with the Aesculap-Meditec MEL 60 excimer laser and Asclepion-Meditec MEL 70 G-Scan excimer
laser.
Results: Four types of folds and striae were described: pseudostriae,
vertical or oblique folds at the hinge of the flap, small faint in stroma and deep,
irregular striae or folds in stroma.
Conclusions: Corneal flap striae and folds, which we can see as a Laser
in situ Keratomileusis complications have a variety of appearances and different
postoperative courses, that require accurate diagnosis and management. |
| Słowa kluczowe: |
laser excimerowy, LASIK, powikłania, opatrunkowe soczewki
kontaktowe. |
| Key words: |
excimer laser, LASIK, complications, bandage contact lenses. |
|
|
|
|
|
|