NR 6/2003

|
|
|
|
|
|
|
|
|
Chirurgiczna korekcja wad refrakcji metodą
wszczepów wewnątrzgałkowych - wyniki własne
Correction of high myopia with anterior chamber
angle-supported phakic intraocular lenses - own results
Stanisława Gierek-Ciaciura, Krzysztof Ochalik, Ariadna
Gierek-Łapińska, Barbara Myga
Z Samodzielnego Publicznego Szpitala Klinicznego nr 5 Śląskiej Akademii Medycznej w
Katowicach
Kierownik: prof. dr hab. n. med. Ariadna Gierek-Łapińska |
|
|
| Summary: |
Purpose: To evaluate the early results:
predictability, efficacy and safety of implanting new model of anterior chamber IOL for
high myopia.
Material and methods: ICARE myopia lens (Corneal) was implanted in 20
eyes of 12 patients with preoperative myopia that ranged from -10D to -23,5D. Mean patient
age was 32,3 years. The follow-up period was 6 months. The desired outcome was emmetropia.
Results: Eighteen eyes (85%) had a postoperative refraction at the last
follow-up examination in a range ?1,0 D of emmetropia. The postoperative refraction
remained stable during the entire follow-up period. Mean visual acuity before surgery,
corrected with spectacle improved from 0,5 to 0,68 postoperatively without glasses in 3
months time. There was no loss in visual acuity after operation. We didn't encounter major
complications. Mean endothelial cell density reduction was 3,2% in our 3 months study.
Conclusions: Implantation of ICARE myopia lens to correct high myopia
resulted in a stable and predictable refractive outcome. Further investigation is
necessary to evaluate long-term stability and safety of this procedure. |
| Słowa kluczowe: |
wysoka krótkowzroczność, wewnątrzgałkowe
przedniokomorowe soczewki fakijne. |
| Key words: |
high myopia, anterior chamber phakic intraocular lenses. |
|
|
|
|
|
|