Wpływ usunięcia oleju silikonowego na ciśnienie wewnątrzgałkowe w oczach po witrektomii

The influence of silicone oil removal on intraocular pressure

Agata Wesołek-Czernik

Z Katedry i Kliniki Chorób Oczu Akademii Medycznej w Łodzi
Kierownik: dr hab. n. med. Wojciech Omulecki

Summary: Purpose: The aim of this study was to evaluate the influence of silicone oil removal on intraocular pressure.
Material and method: Our material consists of 98 patients ( 104 eyes ), who underwent vitrectomy with silicone oil tamponade. Sixteen eyes in this group were aphakic before vitrectomy. The mean duration of silicone-oil tamponade was 8. 8 months. We examined and compared intraocular pressure in all cases before vitrectomy, during tamponade and after silicone oil removal.
Results: The increased intraocular pressure (>22 mmHg) was found in 27 eyes (seven of them were aphakic) during tamponade. We had to remove silicone oil due to glaucoma in 6 eyes (three of them were aphakic ). In 9 eyes (four aphakic) the intraocular pressure was higher than 22 mmHg after silicone oil removal. Seven patients required additional topical medication and 2 patients were qualified for operation - trabeculectomy. Hypotony (<10 mmHg) was observed in 11eyes, and it coexisted with retinal redetachment in 4 cases.
Conclusions: The increased intraocular pressure is a frequent complication of silicone oil tamponade, and it normalizes after silicone oil removal in most of these cases.
Słowa kluczowe: witrektomia z tamponadą olejem silikonowym, jaskra wtórna, usunięcie oleju silikonowego.
Key words: vitrectomy with silicone oil tamponade, secondary glaucoma, silicone oil removal.